Heating fitters and technicians who perform commissioning and maintenance of hot water and residential heating systems need a reliable and stable measuring instrument with which they can easily perform their measuring tasks such as exhaust gas analyses. Th
Heating fitters and technicians who perform commissioning and maintenance of hot water and residential heating systems need a reliable and stable measuring instrument with which they can easily perform their measuring tasks such as exhaust gas analyses. The new testo 310 II provides individual support for their daily measurement tasks and makes their day-to-day work easier.3 Year Warranty (2 Year Manufacturer Warranty + Bonus 1 Year Instrument Choice Warranty)0563-3104 Features: – Simultaneous, individual measurement and display of all relevant measurement parameters by (O2, CO, CO2, flue gas and ambient temperature, CO environment, draught and pressure). Display configurable via the testo Smart App- Simultaneous, additional measurements via the testo Smart App (e.g. gas flow pressure, flow and return temperature)- Easy and intuitive menu guidance- Digital documentation, data transfer and customer data management via testo Smart App
– Comes with a Bluetooth printer with IrDA interface
Temperature – TC Type K (NiCr-Ni) – Measuring range: -20 to +100 C- Accuracy: +/- 1 C- Resolution: 0.1 C- Reaction time: less than 50 sTemperature (ambient temperature)/Temperature – TC Type J (Fe-CuNi) – Measuring range: 0 to +400 C- Accuracy: +/- 1 C (0 to +100 C) / +/- 1.5 % of mv (less than 100 C)- Resolution: 0.1 C- Reaction time: less than 50 sTemperature (Flue gas Oxygen) – Measuring range: 0 to 21 Vol.%- Accuracy: +/- 0.2 Vol.%- Resolution: 0.1 Vol.%- Reaction time t: 30 sDifferential Pressure flue gas Draught – Piezoresistive – Measuring range: -20 to +20 hPa- Accuracy: +/- 0.03 hPa (-3.00 to +3.00 hPa) / +/- 1.5 % of mv (Remaining Range)- Resolution: 0.01 hPaFlue gas degree of effectivity, Eta (calculated) – Measuring range: 0 to 120 %- Resolution: 0.1 %Flue gas loss (calculated) – Measuring range: 0 to 99.9 %- Resolution: 0.1 %Pressure measurement – Measuring range: -40 to +40 hPa- Accuracy: +/- 0.5 hPa- Resolution: 0.1 hPaFlue gas CO (without H-compensation) – Measuring range: 0 to 4000 ppm- Accuracy: +/- 20 ppm (0 to 400 ppm) / +/- 5 % of mv (401 to 2000 ppm) / +/- 10 % of mv (2001 to 4000 ppm)- Resolution: 1 ppm- Reaction time t: 60 sAmbient CO – Measuring range: 0 to 4000 ppm- Accuracy: +/- 20 ppm (0 to 400 ppm) / +/- 5 % of mv (401 to 2000 ppm) / +/- 10 % of mv (2001 to 4000 ppm)- Resolution: 1 ppm- Reaction time: 60 s
$25
We offer free shipping on orders over $30. Please check the free - shipping eligibility at checkout.
It usually takes [3-5] business days for standard shipping. Please note that this is an estimated time frame and may be affected by local holidays, and unforeseen circumstances.
Reviews
There are no reviews yet.