The GL2000 is a high voltage and high speed multichannel data logger equipped with an isolated input mechanism to protect signals from interferences caused by noise from other channels. It adopts a 16-bit A/D converter to achieve hi-speed and hi-resolution
The GL2000 is a high voltage and high speed multichannel data logger equipped with an isolated input mechanism to protect signals from interferences caused by noise from other channels. It adopts a 16-bit A/D converter to achieve hi-speed and hi-resolution measurement.
Features:
– Equipped with an isolated input mechanism to protect signals from interferences caused by noise from other channels. 16-bit A/D converter adopted to achieve hi-speed and hi-resolution measurement.
– Utilizes simultaneous sampling to eliminate slowdown in sampling rate by using multiple A/D converters in simultaneous sampling method. Four individual A/D converters in each channel sustains the maximum sampling speed for all four channels to measure high speed rapid voltage fluctuation and multi-channel vibration measurement.
– Sampling of the logger is performed in sync with an external device using an external signal input. Maximum input frequency: 100 kHz
– CAT III 600 V is compatible with measuring power supply circuit in an equipment that captures power directly from the distribution panel.
– Measures abnormalities in a repeated waveform by effectively measuring the corresponding RMS value. In 1000 Vrms range, Crest Factor is up to 1.41 * Maximum rated safety voltage: 600 V rms, Peak voltage: 850V, In other range, Crest Factor is up to 2.0
– Measured voltage value can be converted to a specified engineering unit. The value can be displayed with the physical measurement value of the sensor and be saved into the data file with the converted values.
– Four arithmetic operations (Addition, subtraction, multiplication and division) are available using two analog input channels.* Data can be saved only in GBD file format.
– The trigger in this unit has multiple functions including level trigger of input signal value for each channel.
– Threshold of an alarm can be set for each channel. When an alarm occurs, notification is sent by following methods.
– Displays data with analog waveform and digital value. Screen can also be split into 1, 2, 4 or 8 zones to display the channels in different zones.
– Displays current data in digital value and results of real time statistical calculation. (Function: Maximum, Minimum, Peak-to-peak, and Average)
– Display the past part of the data while capturing data. Execute without stopping measurement and also scroll past data. Data screen can be switched with past and current.
$25
We offer free shipping on orders over $30. Please check the free - shipping eligibility at checkout.
It usually takes [3-5] business days for standard shipping. Please note that this is an estimated time frame and may be affected by local holidays, and unforeseen circumstances.
Reviews
There are no reviews yet.